Cable
Every pump set supplied with 3 mtr. of cable length. Since pump sets are to be installed in borewell, an additional cable length is required to the electric supply located at ground level. The exact size of the cable is to be selected with the help of cable selection chart.
Control Panel
User is advised to use control panel with quality accessories to avoid future problems. Control panel should have following protective devices for trouble free operation of the pump set
Thermal relay with suitable current relay setting.
Single phasing preventor (For 3 phase pumps only)
Provision for water level guard/ Auto switch connection to avoid dry running of the pump set
Starting and running capacitors (as per specification on motor nameplate)
Overload / Under voltage protector.
Water Level Guard / Dryrun Control
It is recommended to install the pump set with water level guard / dryrun control of reputed make to protect the pump set against dry running at lower water levels. The water level guard consists of a cable & probe. This probe is to be installed at about 0.5 mtr. above N. R. V. top. When the water level in the bore gets lowered below the probe level, starter will get switched off automatically by the level sensing device.
Supporting Clamps
Two pairs of supporting clamps are required for installation of pump set. One pair is required permanently to hold the pump set in position. This clamp usually rests on girders or borewell casing pipe.
Cable Clips
It is necessary to fix a cable at every 3 mtr. length of delivery pipe to keep the cable in position. This minimizes the chances of damage to cable while lowering / taking out of pump set in to / form borewell. Care is to be taken while fixing these clips so that damage to the cable is avoided.
Borewell Cap
It is necessary to cover the borewell opening with this cap to avoid entry of any foreign material like dirty water, stones etc. in to the borewell there by avoiding damage to the pump set. Sometimes if a larger size stone falls into the borewell and is sandwiched between delivery pipe & borewell wall, it can damage the cable or may make it difficult to lift pump set outside.
Check Valve
The pump set operating point can be adjusted using the valve, there by avoiding the pump set operation at very low or high discharge flow.
Non Return Valve
It is recommended to protect the piping system in case of sudden power failures, causing water hammer by fitting N.R.V. in the delivery pipe.
Pressure Gauge
It is recommended to fix a Bourdon tube type pressure gauge in order to indicate the pressure developed by the pump set.
Required Tools For Installation
A tripod stand of 20 feet length.
A chain- pully block of 1 Ton capacity for bore upto 100m. depth & 2 Ton for above 100m. depth installation.
Chain spanner – 2 Nos.
A screw driver 8″, 12″, Insulating pliers, Spanners etc.
Megger 500 Mohm -1 No.
All plumbing material.